FieldPiece USA - SCL2 Carbon Dioxide (CO2 R744) Leak Detector - sensitivity 6 grams/year
The SCL2 is a portable CO2 (R-744) leak detector with a superior combination of sensitivity, speed, sensor life, battery life, portability, and ease of use.
Find leaks on commercial refrigeration systems, restaurant soda machines, or any other system using R-744.
Pinpoint tiny leaks in high concentration CO2 environments with ease. Gas is pumped through the tip of the wand into the sensor within the SCL2 body.
The sensor detects changes in concentration, not absolute concentration, allowing the SCL2 to differentiate CO2 concentrations higher than concentrations normally found in ambient air.
The SCL2 detects leaks as small as 6 grams/yr (0.2 oz/yr).
The SCL2 has three sensitivity settings to keep false triggering to a minimum.
A quick and automatic 30 second selfcalibration upon power-up ensures optimal performance.
The SCL2 comes with a wall and car charger for its ultra-compact lithium-ion battery which powers the SCL2 for 8hrs of continuous operation before a recharge is needed.
Features:
- Find R-744 refrigerant leaks
- Long-life sensor made to last up to ten years
- Three sensitivity levels down to 6g (0.2oz) per year
- Senses change: works in contaminated environments
- Rechargeable lithium ion battery with two chargers
Technical Data:
- Sensing element: Enhanced infrared photo optics
- Sensor life: Up to 10 years
- Refrigerants: R-744 Carbon Dioxide (CO2)
- Sensitivity Levels:
- High: Up to 6 grams/yr (0.2oz/yr)
- Medium: Up to 14 grams/yr (0.5oz/yr)
- Low: Up to 28 grams/yr (1oz/yr)
- Response time: 1 second
- Recovery time: ~4 seconds
- Auto off: 10 minutes after no activity
- Charger: Wall power supply (version with EUROPEAN plug) and car charger supplied
- Battery: 3.7VDC(nominal), rechargeable lithium ion user-replaceable battery
- Battery life: 8 hours continuous use prior to needing a charge. Degradation (30%) after 500 charge/discharge cycles or two years, whichever comes first
- Low battery LED: Lights when approximately 1 hour of battery life remains
- Charge time: Less than 4 hours (either charger)
- Operating environment: 32ºF (0°C) to 104ºF (40°C) at <75%RH (non-condensing)
- Storage environment: <80%RH meter and battery
- For 80% battery recovery: -4ºF (-20°C) to 140ºF (60°C) less than 1 month -4ºF (-20°C) to 113ºF (45°C) less than 3 months -4ºF (-20°C) to 68ºF (20°C) less than 1 year