    1774 IPCC
Following new
Fgas Reg. (EU) 2024/573

Temperature Range

image image
Share:

Kryon® 407C The refrigerant used in home air conditioning

Kryon® 407C is a zeotropic ternary mixture composed of HFC-32/HFC-125/HFC-134a. It has been developed as a replacement for R-22 (HFC-22). Il Kryon® 407C is a non ozone depleting refrigerant and lends itself to many uses in refrigeration and air conditioning systems.

Kryon® 407C is a zeotropic ternary mixture that, unlike azeotropic fluid, changes its temperature during evaporation and condensation phases, for a given value of pressure. Kryon® 407C has a moderate T° Glide (5÷7 °C). Therefore it is very important that Kryon® 407C is transferred only as a liquid state when charging a system, and not as a vapour state. That would cause a change in the composition of the refrigerant, which could damage the plant.
 
Applications
 
Kryon® 407C is used in home and small shop air conditioning systems.
Kryon® 407C is also used in water chillers not provided with centrifugal compressor, and in mediumtemperature refrigeration systems.
 
Performance
 
  • Minimum capacity reduction compared to R-22.
  • Because of its characteristics similar to R-22, Kryon® 407C can be used in conversion fluid in systems that usually use R-22.
  • Changes in the project to achieve a performance optimization are minimum.
 
Recommended Lubricants
 
When using Kryon® 407C in conversion of systems working with R-22, some changes in the system are necessary, as for example the replacement of lubricant.
Mineral oils and alkylbenzene lubricants are immiscible with Kryon® 407C. Please get in touch with the plant manufacturer for recommended lubrificant.
 
Signup or Signin for Download

Data sheet Signup or Signin for Download
Material Safety Data Sheet Signup or Signin for Download
Enthalpy–entropy chart Signup or Signin for Download

Properties of Containers

The containers provided by GENERAL GAS Srl for the delivery and use of the product supplied, shall remain the exclusive property of GENERAL GAS Srl.
Where containers in which the Goods are delivered are to remain the property of General Gas, the Buyer shall return the same to GENERAL GAS Srl in accordance with General Gas’s instructions, empty and in good/safe condition.
The Buyer shall return the containers empty and in good/safe condition, ex-warehouse of origin at its own expense within:
  • refillable refrigerant refillable cylinders: 180 (one.hundred.eighty) days from the date of delivery
  • refillable refrigerant ton-tanks: 60 (sixty) days from the date of delivery
  • refillable high pressure industrial gas cylinders (nitrogen/oxygen/acetylene etc.): 60 (sixty) days from the date of delivery
GENERAL GAS Srl shall be entitled to retain any deposit given by the Buyer to General Gas in respect of such containers if they are not returned on or before the expiry of the specified period from the date of delivery.
If the containers are not returned in good/safe conditions, thus damaged in such a way to make their use dangerous or banned, GENERAL GAS Srl will be entitled to charge the Buyer of the replacement value of the container, counted at the manufacturer’s official price list value, effective at the date. Valves and fittings, if damaged or missing, will be charged the same way.

Proper Use of Containers

The Buyer shall not refill or use any cylinders/containers supplied by GENERAL GAS Srl for anything other than its permitted purposes, and shall not permit others to do the same. The containers shall only be used for the transport and storage of products for which they are intended; it is therefore absolutely precluded any different use. The containers supplied by GENERAL GAS Srl comply with the regulations in force; therefore, the Buyer will be the only subject responsible of the proper use of container. No responsibility can never be charged to GENERAL GAS Srl if the containers are improperly used or used by the Buyer for scopes others than the permitted ones. The Buyer is not authorized to deliver, even on a temporary basis, the containers - exclusive property of GENERAL GAS Srl - to others to make it fill; the Buyer is the sole responsible for the containers from the time of delivery until they are returned to the GENERAL GAS Srl warehouse.