R454B Opteon® XL41 - T-PED returnable to-tank 920 Lt - 800 kg (valve 21,8 x 1/14 LH)


R454B Opteon® XL41 in fusto a Rendere 920 Lt - 800 Kg (valvola 21,8 x 1/14 LH) - Foto 1
R454B Opteon® XL41 in fusto a Rendere 920 Lt - 800 Kg (valvola 21,8 x 1/14 LH) - Foto 2

RFQ for large quantities
(minimum 10 pcs)
Need to buy large quantities? Contact us for a customized proposal.

image
image
image
image
    465 IPCC
Following new
Fgas Reg. (EU) 2024/573

Temperature Range

image
Share:

Opteon™ XL41 (R-454B) is a mildly flammable low global warming potential (GWP) hydrofluoro-olefin (HFO) based refrigerant to replace R-410A in new equipment designs.

It offers the optimal balance of properties to replace R-410A in positive displacement, direct expansion air conditioning, heat pump and chiller applications.

It is the lowest GWP Opteon™ replacement for R-410A (78% reduction) and provides improved performance.

Opteon™ XL41 offers similar properties to R-410A which makes it easy and cost-effective to apply in new equipment without major modifications.

Opteon™ XL41 is classified as a mildly flammable (ISO/ASHRAE class 2L) refrigerant. Please check your local regulations and Standards such as PED, EN 378 or ISO 5149 to verify the allowable filling charge, new
equipment design and safe handling requirements for the intended application.


Applications

  • Positive displacement, DX air conditioning, heat pumps and chillers
    • Residential, light commercial, commercial
  • Direct replacement for all equipment types designed for R-410A
    • Window units, portables, mini-splits, ducted splits, PTACs, multi-splits, DX chillers, and other

Benefits

  • Lowest GWP replacement for R-410A (reduction of 78 %); best where lowest GWP is required
  • Improved capacity and efficiency compared to R-410A
  • Excellent performance in normal and high ambient conditions
  • Very close match to R-410A – easily convertible from R-410A design with minimal changes
  • Very low temperature glide – can be topped off after leaks
  • Non-toxic and mildly flammable (ISO/ASHRAE 3) A2L)
  • Allows >1.7 kg minimum filling charge under new Codes & Standards (e.g. ISO 5149 or EN 378)
  • Miscible with POE lubricants
Signup or Signin for Download

Data sheet Signup or Signin for Download
Material Safety Data Sheet Signup or Signin for Download
Enthalpy–entropy chart Signup or Signin for Download

Properties of Containers

The containers provided by GENERAL GAS Srl for the delivery and use of the product supplied, shall remain the exclusive property of GENERAL GAS Srl.
Where containers in which the Goods are delivered are to remain the property of General Gas, the Buyer shall return the same to GENERAL GAS Srl in accordance with General Gas’s instructions, empty and in good/safe condition.
The Buyer shall return the containers empty and in good/safe condition, ex-warehouse of origin at its own expense within:
  • refillable refrigerant refillable cylinders: 180 (one.hundred.eighty) days from the date of delivery
  • refillable refrigerant ton-tanks: 60 (sixty) days from the date of delivery
  • refillable high pressure industrial gas cylinders (nitrogen/oxygen/acetylene etc.): 60 (sixty) days from the date of delivery
GENERAL GAS Srl shall be entitled to retain any deposit given by the Buyer to General Gas in respect of such containers if they are not returned on or before the expiry of the specified period from the date of delivery.
If the containers are not returned in good/safe conditions, thus damaged in such a way to make their use dangerous or banned, GENERAL GAS Srl will be entitled to charge the Buyer of the replacement value of the container, counted at the manufacturer’s official price list value, effective at the date. Valves and fittings, if damaged or missing, will be charged the same way.

Proper Use of Containers

The Buyer shall not refill or use any cylinders/containers supplied by GENERAL GAS Srl for anything other than its permitted purposes, and shall not permit others to do the same. The containers shall only be used for the transport and storage of products for which they are intended; it is therefore absolutely precluded any different use. The containers supplied by GENERAL GAS Srl comply with the regulations in force; therefore, the Buyer will be the only subject responsible of the proper use of container. No responsibility can never be charged to GENERAL GAS Srl if the containers are improperly used or used by the Buyer for scopes others than the permitted ones. The Buyer is not authorized to deliver, even on a temporary basis, the containers - exclusive property of GENERAL GAS Srl - to others to make it fill; the Buyer is the sole responsible for the containers from the time of delivery until they are returned to the GENERAL GAS Srl warehouse.