I am already customer

If you already have an account, please login with your credentials


Forgot password?

Are you a new customer?
Register Now

By creating an account, you can make the purchase and access other services

Create an Account

R455A Solstice® L40X (HFO-HFC-CO2) in returnable drum 920 Lt - 798 Kg - T-PED


R455A Solstice® L40X (HFO-HFC-CO2) in Fusto a Rendere 920 Lt - 798 Kg - Foto 1

RFQ for large quantities
(minimum 10 pcs)
Need to buy large quantities? Contact us for a customized proposal.

image
image
image
image
    146
    IPCC AR4 (AR5)

Temperature Range

image image image
Share:
Solstice® L40X (R-455A): the alternative to R404A/R507 with Ultra Low GWP for the plug-ins
 
Characteristics Solstice L40X (R-455A) is a mildly flammable, zeotropic blend designed to serve as an alternative for low, medium and high temperature applications in new systems.
Its ultra-low GWP of only 145 (below 150) makes it an Fgas-ready solution. Plus, it provides a close capacity match to R-404A, extended operating envelope when compared to propane or air- conditioning refrigerants, and high energy efficiency.
 
Applications:
Solstice L40X (R-455A) is an excellent refrigerant option for commercial refrigeration low temperature applications like plug-ins, condensing units, foodservice, water-loop systems and other similar. Its low GWP, extended operating envelope, high effi ciency, high critical temperature and low critical pressure, makes it a potential match for other applications such as supermarkets, chillers, heatpumps, transport refrigeration, etc.
 
Materials compatibility:
Honeywell does not recommend the use of chlorinated solvents to clean refrigeration systems or components.
 
Desiccants:
Desiccant driers compatible with Solstice L40X are commercially available. Individual drier manufacturers should be contacted for specific recommendations.
 
Lubricants:
POE (polyol ester) oil is recommended for using Solstice L40X. Compressor manufacturers typically qualify specific lubricants for use with their products. Users should check with the equipment manufacturer for the recommended lubricants for their system.
 
Plastics and elastomers:
Solstice L40X is compatible with most common materials. Since there are many different grades and formulations of these materials, we recommend that compatibility testing be performed on the specific grade of materials under consideration and at the conditions of use when designing new systems. Customers should consult the manufacturer or conduct further independent testing.
 
Signup or Signin for Download

Data sheet Signup or Signin for Download
Material Safety Data Sheet Signup or Signin for Download
Enthalpy–entropy chart Signup or Signin for Download
Case Study Zanotti - application on monoblock cooling systems (MT) Signup or Signin for Download

Properties of Containers

The containers provided by GENERAL GAS Srl for the delivery and use of the product supplied, shall remain the exclusive property of GENERAL GAS Srl.
Where containers in which the Goods are delivered are to remain the property of General Gas, the Buyer shall return the same to GENERAL GAS Srl in accordance with General Gas’s instructions, empty and in good/safe condition.
The Buyer shall return the containers empty and in good/safe condition, ex-warehouse of origin at its own expense within:
  • refillable refrigerant refillable cylinders: 180 (one.hundred.eighty) days from the date of delivery
  • refillable refrigerant ton-tanks: 60 (sixty) days from the date of delivery
  • refillable high pressure industrial gas cylinders (nitrogen/oxygen/acetylene etc.): 60 (sixty) days from the date of delivery
GENERAL GAS Srl shall be entitled to retain any deposit given by the Buyer to General Gas in respect of such containers if they are not returned on or before the expiry of the specified period from the date of delivery.
If the containers are not returned in good/safe conditions, thus damaged in such a way to make their use dangerous or banned, GENERAL GAS Srl will be entitled to charge the Buyer of the replacement value of the container, counted at the manufacturer’s official price list value, effective at the date. Valves and fittings, if damaged or missing, will be charged the same way.

Proper Use of Containers

The Buyer shall not refill or use any cylinders/containers supplied by GENERAL GAS Srl for anything other than its permitted purposes, and shall not permit others to do the same. The containers shall only be used for the transport and storage of products for which they are intended; it is therefore absolutely precluded any different use. The containers supplied by GENERAL GAS Srl comply with the regulations in force; therefore, the Buyer will be the only subject responsible of the proper use of container. No responsibility can never be charged to GENERAL GAS Srl if the containers are improperly used or used by the Buyer for scopes others than the permitted ones. The Buyer is not authorized to deliver, even on a temporary basis, the containers - exclusive property of GENERAL GAS Srl - to others to make it fill; the Buyer is the sole responsible for the containers from the time of delivery until they are returned to the GENERAL GAS Srl warehouse.

Other Formats