    148 (146)
    IPCC AR4 (AR5)

Temperature Range

image image
Share:

Solstice® N71 (R-471A) is Honeywell's new nonflammable, nontoxic, hydrofluoro-olefin (HFO)-based refrigerant that meets the ambitious requirements of FGas 2024 (new EU Regulation No. 2024/573 effective 11/3/2024), and offers significant economic benefits for both installation and maintenance.

NOTE: commercialisation of the refrigerant R471A is planned from Q4 2024 - Q1 2025

Let's find out together 4 reasons why it should be your refrigerant of choice for new equipment in medium-temperature applications.

A) IMPROVES ENERGY EFFICIENCY: Solstice® N71 enables medium-temperature commercial refrigeration systems to deliver energy efficiency improvements equal to:

Calculations based on thermodynamic analysis under the following conditions:
(1) ASHRAE standard evaporation temperature MT for R404A, R471A, CO2 ; (2) Evap. superheat. equal to 9 K for R404A, R471A, CO2 ; (3) Suction superheat of 18 K for R404A, R471A, CO2 ; (4) Compressing isentropic effciency of 65%, volumetric effciency of 100% for R404A, R471A, CO2 ; (5) Ambient temperature of 29.5 °C; Condensation temperature of 40.50 °C (no subcooling) for R404A and R471A; for CO2 Exit temperature from gas cooler of 31.67 °C and -15.6 °C approach; (6) Cooler gas pressure for CO2 of 83 bar (1204 psia); (7) The cooling capacities of R404A, R471A, CO2 are equalized

B) MAKE YOUR INSTALLATION AND MAINTENANCE PROCESS EASIER: Solstice® N71 is suitable for a wide range of system architectures that perfectly match the design of MV direct expansion systems, keeping the system safe, functional, and energy efficient. Handling, storage, and transport are identical to those of any non-infiammable low-pressure refrigerant: experience or technical skills already used in conventional refrigeration are required. Therefore, you have more choice about the technicians to whom you entrust the installation, maintenance, and service.

C) REDUCES TOTAL OWNERSHIP COST (TCO): Thanks to the efficiency of Solstice® N71, you can cut energy costs and achieve lower total CO2 emissions (TEWI, sum of direct + indirect emissions) in the environment than both old and new generation systems (e.g., R744). By using conventional refrigeration equipment and practices, you avoid paying a surcharge for installation and routine and extraordinary maintenance. It also reduces the risk and unforeseen expenses associated with critical failures that can occur, for example, in high-pressure CO2 refrigeration systems.

D) MEETS SUSTAINABILITY OBJECTIVES: Solstice® N71 is a low-pressure refrigerant and has a GWP <150, this allows for reduced gas leakage and definite emissions in "Scope 1." It also complies with international standards. In addition, because it is more energy efficient than CO2, it helps reduce overall carbon emissions and conserve natural resources.

THE REFRIGERANT WE'VE ALL BEEN WAITING FOR: RETROFITS & NEW INSTALLATIONS!

Class A1 infiammability allows design according to known standards and without costly retrofits in the construction and installation of cooling systems.
Suitable for high ambient temperatures: low condensing pressure, reliability and resilience in extreme conditions, even in tropical environments; unmatched energy efficiency in direct expansion.

 

Signup or Signin for Download

Enthalpy–entropy chart Signup or Signin for Download

Properties of Containers

The containers provided by GENERAL GAS Srl for the delivery and use of the product supplied, shall remain the exclusive property of GENERAL GAS Srl.
Where containers in which the Goods are delivered are to remain the property of General Gas, the Buyer shall return the same to GENERAL GAS Srl in accordance with General Gas’s instructions, empty and in good/safe condition.
The Buyer shall return the containers empty and in good/safe condition, ex-warehouse of origin at its own expense within:
  • refillable refrigerant refillable cylinders: 180 (one.hundred.eighty) days from the date of delivery
  • refillable refrigerant ton-tanks: 60 (sixty) days from the date of delivery
  • refillable high pressure industrial gas cylinders (nitrogen/oxygen/acetylene etc.): 60 (sixty) days from the date of delivery
GENERAL GAS Srl shall be entitled to retain any deposit given by the Buyer to General Gas in respect of such containers if they are not returned on or before the expiry of the specified period from the date of delivery.
If the containers are not returned in good/safe conditions, thus damaged in such a way to make their use dangerous or banned, GENERAL GAS Srl will be entitled to charge the Buyer of the replacement value of the container, counted at the manufacturer’s official price list value, effective at the date. Valves and fittings, if damaged or missing, will be charged the same way.

Proper Use of Containers

The Buyer shall not refill or use any cylinders/containers supplied by GENERAL GAS Srl for anything other than its permitted purposes, and shall not permit others to do the same. The containers shall only be used for the transport and storage of products for which they are intended; it is therefore absolutely precluded any different use. The containers supplied by GENERAL GAS Srl comply with the regulations in force; therefore, the Buyer will be the only subject responsible of the proper use of container. No responsibility can never be charged to GENERAL GAS Srl if the containers are improperly used or used by the Buyer for scopes others than the permitted ones. The Buyer is not authorized to deliver, even on a temporary basis, the containers - exclusive property of GENERAL GAS Srl - to others to make it fill; the Buyer is the sole responsible for the containers from the time of delivery until they are returned to the GENERAL GAS Srl warehouse.